Byotrol PROCESSUS Enzymatic Instrument Cleaner

Note: Please note that liquids will be shipped separately and may arrive independently from the rest of your order.

Formerly known as REPROZYME and REPRODIS, PROCESSUS is a 360-degree instrument decontamination system, powered by Byotrol.

Formulated for powerful pre-disinfection cleaning, PROCESSUS Enzymatic Instrument Cleaner effectively removes organic matter to protect and maintain the quality of surgical instruments and equipment. This economical concentrate uses a combination of effective enzymes to break down organic matter in just 10 minutes, making it ideal for use manually or in ultrasonic baths. Suitable for use on a wide range of equipment including flexible and rigid endoscopes, ET tubes and more.

Follow with PROCESSUS Instrument Disinfectant and autoclaving where required.

✚ 2 Litre Self Dosing Bottle

Added Benefits:

✚ Convenient self-dosing bottle aids correct dilution, reducing end-user error

✚ All packaging 100% recyclable after use

✚ Manufactured in the UK

✚ Biodegradable formulation

✚ Fast 10 minute contact time saves valuable time

✚ Economical concentrate format diluted to 2% (20ml per 1 litre finished solution)

✚ Each bottle makes 100 litres of finished solution saving valuable resources

✚ Dissolves and removes proteinaceous and organic material including blood, saliva, mucus and faeces

✚ Suitable for use on a wide range of surgical instruments and equipment including endoscopes and fine lumen

What makes this product a sustainable choice?

Locally Sourced
Products made in the United Kingdom.


Directions for Use:

Refer to the safety data sheet prior to use.

1. Dilute concentrate at 2%, adding purified water first, then PROCESSUS Enzymatic Instrument Cleaner.

2. Add diluted solution to suitable container for manual cleaning or ultrasonic bath.

3. Record date of dilution and dilution rate.

4. Disassemble instruments / equipment in accordance with manufacturer’s instructions.

5. Rinse instruments / equipment with clean water first to remove gross debris.

6. Submerge instruments in the enzymatic solution and leave for 10 minutes. If cleaning endoscopes, ensure solution is flushed through the internal lumens/s.

7. Remove instruments and rinse with clean water.

 

Follow with PROCESSUS Instrument Disinfectant and autoclaving when required.

Ensure containers of diluted liquid are covered to avoid environmental contamination. Diluted product must be disposed of after 7 days, or sooner if the liquid becomes cloudy or contaminated.